American Power Design X50 Series 50.0 Watt

$555.00

  • Customer Selects Output Voltage
  • Outputs to 1000Vdc
  • Excellent Line & Load Regulation
  • Independently Isolated Outputs
  • Ultra Wide Input Range
  • 1 kVdc Output Isolation
  • Continuous Short Circuit Protection
  • Remote On/Off Control
SKU: APDX50 Category:

The X50 Series of DC/DC converters accepts wide input ranges of 9-36Vdc, 20-60Vdc, 36-72Vdc. Outputs are isolated to 1 kVdc. In the case of duals, the outputs are completely independent including overload protection. All models will tolerate a short circuit indefinitely. Also included is a PI Network input filter and remote on/off.

emp. (Stability): 0.02%/Deg C
Temp. (Operating Case): -45 to +85 Deg C 
Temp. (Storage): -55 to +100 Deg C
EMI/RFI: Six Sided Shield
Derating: None 
Cooling: Free-Air Convection

* All models designed to meet IEC/UL/CSA/EN 62368

* * For RoHS Compliant part, add suffix /Y

Input Ranges: 9-36Vdc, 20-60Vdc, 36-72Vdc
Voltage Accuracy: 1% / 1%
Line Regulation: 0.1%
Load Regulation: 0.3%
Output Ripple: 0.4%
Input Filter: PI Network
Efficiency: 87%
Short Circuit Protection: Continuous
Switching Frequency: 120 kHz
Isolation: 1 kVdc

Models Currently In Production

* * For RoHS Compliant part denoted by /Y

Output VoltageCurrentInput VoltageEfficiencyPowerModel Number
48.0 Vdc1 A9.0-36.0 Vdc87%48.0W
X50-48 
X50-48/Y
48.0 Vdc
48.0 Vdc
500 mA
500 mA
9.0-36.0 Vdc87%48.0W
X50-48/48 
X50-48/48/Y
48.0 Vdc
48.0 Vdc
500 mA
500 mA
20.0-60.0 Vdc87%48.0W
X50-48/48/B 
X50-48/48/B/Y
48.0 Vdc
48.0 Vdc
500 mA
500 mA
36.0-72.0 Vdc87%48.0W
X50-48/48/C 
X50-48/48/C/Y
48.0 Vdc1 A20.0-60.0 Vdc87%48.0W
X50-48/B 
X50-48/B/Y
48.0 Vdc1 A36.0-72.0 Vdc87%48.0W
X50-48/C 
X50-48/C/Y
50.0 Vdc1 A9.0-36.0 Vdc87%50.0W
X50-50 
X50-50/Y
50.0 Vdc
50.0 Vdc
500 mA
500 mA
9.0-36.0 Vdc87%50.0W
X50-50/50 
X50-50/50/Y
50.0 Vdc
50.0 Vdc
500 mA
500 mA
20.0-60.0 Vdc87%50.0W
X50-50/50/B 
X50-50/50/B/Y
50.0 Vdc
50.0 Vdc
500 mA
500 mA
36.0-72.0 Vdc87%50.0W
X50-50/50/C 
X50-50/50/C/Y
50.0 Vdc1 A20.0-60.0 Vdc87%50.0W
X50-50/B 
X50-50/B/Y
50.0 Vdc1 A36.0-72.0 Vdc87%50.0W
X50-50/C 
X50-50/C/Y
75.0 Vdc666 mA9.0-36.0 Vdc87%50.0W
X50-75 
X50-75/Y
75.0 Vdc
75.0 Vdc
333 mA
333 mA
9.0-36.0 Vdc87%50.0W
X50-75/75 
X50-75/75/Y
75.0 Vdc
75.0 Vdc
333 mA
333 mA
20.0-60.0 Vdc87%50.0W
X50-75/75/B 
X50-75/75/B/Y
75.0 Vdc
75.0 Vdc
333 mA
333 mA
36.0-72.0 Vdc87%50.0W
X50-75/75/C 
X50-75/75/C/Y
75.0 Vdc666 mA20.0-60.0 Vdc87%50.0W
X50-75/B 
X50-75/B/Y
75.0 Vdc666 mA36.0-72.0 Vdc87%50.0W
X50-75/C 
X50-75/C/Y
100.0 Vdc500 mA9.0-36.0 Vdc87%50.0W
X50-100 
X50-100/Y
100.0 Vdc
100.0 Vdc
250 mA
250 mA
9.0-36.0 Vdc87%50.0W
X50-100/100 
X50-100/100/Y
100.0 Vdc
100.0 Vdc
250 mA
250 mA
20.0-60.0 Vdc87%50.0W
X50-100/100/B 
X50-100/100/B/Y
100.0 Vdc
100.0 Vdc
250 mA
250 mA
36.0-72.0 Vdc87%50.0W
X50-100/100/C 
X50-100/100/C/Y
100.0 Vdc500 mA20.0-60.0 Vdc87%50.0W
X50-100/B 
X50-100/B/Y
100.0 Vdc500 mA36.0-72.0 Vdc87%50.0W
X50-100/C 
X50-100/C/Y
150.0 Vdc333 mA9.0-36.0 Vdc87%50.0W
X50-150 
X50-150/Y
150.0 Vdc
150.0 Vdc
166 mA
166 mA
9.0-36.0 Vdc87%50.0W
X50-150/150 
X50-150/150/Y
150.0 Vdc
150.0 Vdc
166 mA
166 mA
20.0-60.0 Vdc87%50.0W
X50-150/150/B 
X50-150/150/B/Y
150.0 Vdc
150.0 Vdc
166 mA
166 mA
36.0-72.0 Vdc87%50.0W
X50-150/150/C 
X50-150/150/C/Y
150.0 Vdc333 mA20.0-60.0 Vdc87%50.0W
X50-150/B 
X50-150/B/Y
150.0 Vdc333 mA36.0-72.0 Vdc87%50.0W
X50-150/C 
X50-150/C/Y
200.0 Vdc250 mA9.0-36.0 Vdc87%50.0W
X50-200 
X50-200/Y
200.0 Vdc
200.0 Vdc
125 mA
125 mA
9.0-36.0 Vdc87%50.0W
X50-200/200 
X50-200/200/Y
200.0 Vdc
200.0 Vdc
125 mA
125 mA
20.0-60.0 Vdc87%50.0W
X50-200/200/B 
X50-200/200/B/Y
200.0 Vdc
200.0 Vdc
125 mA
125 mA
36.0-72.0 Vdc87%50.0W
X50-200/200/C 
X50-200/200/C/Y
200.0 Vdc250 mA20.0-60.0 Vdc87%50.0W
X50-200/B 
X50-200/B/Y
200.0 Vdc250 mA36.0-72.0 Vdc87%50.0W
X50-200/C 
X50-200/C/Y
220.0 Vdc
220.0 Vdc
113.6 mA
113.6 mA
9.0-36.0 Vdc89%50.0W
X50-220/220 
X50-220/220/Y
300.0 Vdc166 mA9.0-36.0 Vdc87%50.0W
X50-300 
X50-300/Y
300.0 Vdc
300.0 Vdc
83 mA
83 mA
9.0-36.0 Vdc87%50.0W
X50-300/300 
X50-300/300/Y
300.0 Vdc
300.0 Vdc
83 mA
83 mA
20.0-60.0 Vdc87%50.0W
X50-300/300/B 
X50-300/300/B/Y
300.0 Vdc
300.0 Vdc
83 mA
83 mA
36.0-72.0 Vdc87%50.0W
X50-300/300/C 
X50-300/300/C/Y
300.0 Vdc166 mA20.0-60.0 Vdc87%50.0W
X50-300/B 
X50-300/B/Y
300.0 Vdc166 mA36.0-72.0 Vdc87%50.0W
X50-300/C 
X50-300/C/Y
400.0 Vdc125 mA9.0-36.0 Vdc87%50.0W
X50-400 
X50-400/Y
400.0 Vdc
400.0 Vdc
62 mA
62 mA
9.0-36.0 Vdc87%50.0W
X50-400/400 
X50-400/400/Y
400.0 Vdc
400.0 Vdc
62 mA
62 mA
20.0-60.0 Vdc87%50.0W
X50-400/400/B 
X50-400/400/B/Y
400.0 Vdc
400.0 Vdc
62 mA
62 mA
36.0-72.0 Vdc87%50.0W
X50-400/400/C 
X50-400/400/C/Y
400.0 Vdc125 mA20.0-60.0 Vdc87%50.0W
X50-400/B 
X50-400/B/Y
400.0 Vdc125 mA36.0-72.0 Vdc87%50.0W
X50-400/C 
X50-400/C/Y
405.0 Vdc
405.0 Vdc
61.7 mA
61.7 mA
9.0-36.0 Vdc87%50.0W
X50-405/405 
X50-405/405/Y
405.0 Vdc
405.0 Vdc
61.7 mA
61.7 mA
20.0-60.0 Vdc87%50.0W
X50-405/405/B 
X50-405/405/B/Y
405.0 Vdc
405.0 Vdc
61.7 mA
61.7 mA
36.0-72.0 Vdc87%50.0W
X50-405/405/C 
X50-405/405/C/Y
440.0 Vdc
440.0 Vdc
56.8 mA
56.8 mA
9.0-36.0 Vdc89%50.0W
X50-440/440 
X50-440/440/Y
440.0 Vdc
440.0 Vdc
56.8 mA
56.8 mA
20.0-60.0 Vdc87%50.0W
X50-440/440/B 
X50-440/440/B/Y
440.0 Vdc
440.0 Vdc
56.8 mA
56.8 mA
36.0-72.0 Vdc87%50.0W
X50-440/440/C 
X50-440/440/C/Y
500.0 Vdc100 mA9.0-36.0 Vdc87%50.0W
X50-500 
X50-500/Y
500.0 Vdc
500.0 Vdc
50 mA
50 mA
9.0-36.0 Vdc87%50.0W
X50-500/500 
X50-500/500/Y
500.0 Vdc
500.0 Vdc
50 mA
50 mA
20.0-60.0 Vdc87%50.0W
X50-500/500/B 
X50-500/500/B/Y
500.0 Vdc
500.0 Vdc
50 mA
50 mA
36.0-72.0 Vdc87%50.0W
X50-500/500/C 
X50-500/500/C/Y
500.0 Vdc100 mA20.0-60.0 Vdc87%50.0W
X50-500/B 
X50-500/B/Y
500.0 Vdc100 mA36.0-72.0 Vdc87%50.0W
X50-500/C 
X50-500/C/Y

APD RoHs Certification

American Power Design, Inc. (APD) certifies that APD's products manufactured with the suffix /Y conform to the requirements of the European Union's Restriction on the use of Hazardous Substances in electrical and electronic equipment (RoHs) Directive, 2015/863. Conformance to the RoHs directive is achieved through the elimination of the use of restricted substances in the manufacture of products and through the enforcement of RoHs restrictions with all of APD's vendors/subcontractors.

The table below identifies the RoHs limit on restricted substances and APD certifies that our RoHs products are below the limit for the substances identified.